51. The highest voltage for transmitting electrical power in India is
(a) 33 kV.
(b) 66 kV

(c) 132 kV

(d) 400 kV

Ans: d

52. In a transformer the resistance between its primary and secondary is (a) zero

(b) 1 ohm

(c) 1000 ohms

(d) infinite

Ans: d

53. A transformer oil must be free from

(a) sludge

(b) odour

(c) gases

(d) moisture

Ans: d

54. A Buchholz relay can be installed on

(a) auto-transformers

(b) air-cooled transformers

(c) welding transformers

(d) oil cooled transformers

Ans: d

55. Gas is usually not liberated due to dissociation of transformer oil unless the oil temperature exceeds

(a) 50°C

(b) 80°C

(c) 100°C

(d) 150°C

Ans: d

56. The main reason for generation of harmonics in a transformer could be

(a) fluctuating load

(b) poor insulation

(c) mechanical vibrations

(d) saturation of core

Ans: d

57. Distribution transformers are generally designed for maximum efficiency around (a) 90% load

(b) zero load

(c) 25% load

(d) 50% load

Ans: d

58. Which of the following property is not necessarily desirable in the material for transformer core ? (a) Mechanical strength

(6) Low hysteresis loss

(c) High thermal conductivity

(d) High permeability

Ans: c

59. Star/star transformers work satisfactorily when

(a) load is unbalanced only

(b) load is balanced only

(c) on balanced as well as unbalanced loads

(d) none of the above

Ans: b

60. Delta/star transformer works satisfactorily when

(a) load is balanced only

(b) load is unbalanced only

(c) on balanced as well as unbalanced loads

(d) none of the above

Ans: c

61. Buchholz's relay gives warning and protection against

(a) electrical fault inside the transformer itself

(b) electrical fault outside the transformer in outgoing feeder

(c) for both outside and inside faults

(d) none of the above

Ans: a

62. The magnetising current of a transformer is usually small because it has

(a) small air gap

(b) large leakage flux

(c) laminated silicon steel core

(d) fewer rotating parts

Ans: a

63. Which of the following does not change in an ordinary transformer ?

(a) Frequency

(b) Voltage

(c) Current

(d) Any of the above

Ans: a

64. Which of the following properties is not necessarily desirable for the material for transformer core ? (a) Low hysteresis loss

(b) High permeability

(c) High thermal conductivity

(d) Adequate mechanical strength Ans: c

65. The leakage flux in a transformer depends upon

(a) load current

(b) load current and voltage

(c) load current, voltage and frequency

(d) load current, voltage, frequency and power factor Ans: a

66. The path of the magnetic flux in transformer should have

(a) high reluctance

(b) low reactance

(c) high resistance

(d) low resistance

Ans: b

67. Noise level test in a transformer is a

(a) special test

(b) routine test

(c) type test

(d) none of the above Ans: c

68. Which of the foJIowing is not a routine test on transformers ?

(a) Core insulation voltage test

(b) Impedance test

(c) Radio interference test

(d) Polarity test

Ans: c

69. A transformer can have zero voltage regulation at

(a) leading power factor (b) lagging power factor

(c) unity power factor

(d) zero power factor

Ans: a

70. Helical coils can be used on

(a) low voltage side of high kVA trans¬formers

(b) high frequency transformers

(c) high voltage side of small capacity transformers

(d) high voltage side of high kVA rating transformers Ans: a

71. Harmonics in transformer result in

(a) increased core losses

(b) increased I2R losses

(c) magnetic interference with communication circuits

(d) all of the above

Ans: d

72. The core used in high frequency transformer is usually

(a) copper core

(b) cost iron core

(c) air core

(d) mild steel core

Ans: c

73. The full-load copper loss of a trans¬former is 1600 W. At half-load, the copper loss will be (a) 6400 W

(b) 1600 W

(c) 800 W

(d) 400 W

Ans: d

1.74. The value of flux involved m the e.m.f. equation of a transformer is

(a) average value

(b) r.m.s. value

(c) maximum value

(d) instantaneous value

Ans: c

L.75. Silicon steel used in laminations mainly reduces

(a) hysteresis loss

(b) eddy current losses

(c) copper losses

(d) all of the above Ans: a

76. Which winding of the transformer has less cross-sectional area ?

(a) Primary winding

(b) Secondary winding

(c) Low voltage winding

(d) High voltage winding

Ans: d

77. Power transformers are generally designed to have maximum efficiency around (a) no-load

(b) half-load

(c) near full-load

(d) 10% overload

Ans: c

.78. Which of the following is the main advantage of an auto-transformer over a two winding transformer ?

(a) Hysteresis losses are reduced

(b) Saving in winding material

(c) Copper losses are negligible

(d) Eddy losses are totally eliminated

Ans: b

79. During short circuit test iron losses are negligible because

(a) the current on secondary side is negligible

(b) the voltage on secondary side does not vary

(c) the voltage applied on primary side is low

(d) full-load current is not supplied to the transformer Ans: c

80. Two transformers are connected in parallel. These transformers do not have equal percentage impedance. This is likely to result in

(a) short-circuiting of the secondaries

(b) power factor of one of the trans¬formers is leading while that of the other lagging

(c) transformers having higher copper losses will have negligible core losses

(d) loading of the transformers not in proportion to their kVA ratings Ans: d

81. The changes in volume of transformer cooling oil due to variation of atmospheric temperature during day and

night is taken care of by which part of transformer

(a) Conservator

(b) Breather(c) Bushings

(d) Buchholz relay

Ans: a

82. An ideal transformer is one which has

(a) no losses and magnetic leakage

(b) interleaved primary and secondary windings

(c) a common core for its primary and secondary windings

(d) core of stainless steel and winding of pure copper metal

(e) none of the above

Ans: a

83. When a given transformer is run at its rated voltage but reduced frequency, its

(a) flux density remains unaffected

(b) iron losses are reduced

(c) core flux density is reduced

(d) core flux density is increased

Ans: d

84. In an actual transformer the iron loss remains practically constant from noload to fullload because

(a) value of transformation ratio remains constant

(b) permeability of transformer core remains constant

(c) core flux remains practically constant

(d) primary voltage remains constant

(c) secondary voltage remains constant Ans: c

85. An ideal transformer will have maximum efficiency at a load such that

(a) copper loss = iron loss

(b) copper loss < iron loss

(c) copper loss > iron loss

(d) none of the above

Ans: a

86. If the supply frequency to the transformer is increased,"the iron loss will

(a) not change

(b) decrease

(c) increase

(d) any of the above

Ans: c

87. Negative voltage regulation is indicative that the load is

(a) capacitive only

(b) inductive only

(c) inductive or resistive

(d) none of the above

Ans: a

88. Iron loss of a transformer can be measured by

(a) low power factor wattmeter

(b) unity power factor wattmeter

(c) frequency meter

(d) any type of wattmeter

Ans: a

89. When secondary of a current transformer is open-circuited its iron core will be

(a) hot because of heavy iron losses taking place in it due to high flux density

(b) hot because primary will carry heavy current

(c) cool as there is no secondary current

(d) none of above will happen

Ans: a

90. The transformer laminations are insulated from each other by

(a) mica strip

(6) thin coat of varnish (c) paper

(d) any of the above Ans: b

91. Which type of winding is used in 3phase shell-type transformer ?

(a) Circular type

(b) Sandwich type

(c) Cylindrical type

(d) Rectangular type

Ans: b

92. During open circuit test of a transformer

(a) primary is supplied rated voltage

(b) primary is supplied full-load current

(c) primary is supplied current at reduced voltage

(d) primary is supplied rated kVA Ans: a

93. Open circuit test on transformers is conducted to determine

(a) hysteresis losses

(b) copper losses

(c) core losses

(d) eddy current losses

Ans: c

94. Short circuit test on transformers is conducted to determine

(a) hysteresis losses

(b) copper losses

(c) core losses

(d) eddy current losses

Ans: b

95. For the parallel operation of single phase transformers it is necessary that they should have

(a) same efficiency

(b) same polarity

(c) same kVA rating

(d) same number of turns on the secondary side. Ans: b

96. The transformer oil should have _____ volatility and _____ viscosity.

(a) low,low

(b) high,high

(c) low,high

(d) high,low

Ans: a

97. The function of breather in a transformer is

(a) to provide oxygen inside the tank

(b) to cool the coils during reduced load

(c) to cool the transformer oil

(d) to arrest flow of moisture when outside air enters the transformerAns: d

98. The secondary winding of which of the following transformers is always kept closed ?

(a) Step-up transformer

(b) Step-down transformer

(c) Potential transformer

(d) Current transformer

Ans: d

99. The size of a transformer core will depend on

(a) frequency

(b) area of the core

(c) flux density of the core material

(d) (a) and (b) both

Ans: d

100. N atural air coo ling is generally restricted for transformers up to

(a) 1.5 MVA

(b) 5 MVA

(c) 15 MVA

(d) 50 MVA

Ans: a

101. A shell-type transformer has

(a) high eddy current losses

(b) reduced magnetic leakage

(c) negligibly hysteresis losses

(d) none of the above

Ans: b

102. A transformer can have regulation closer to zero

(a) on full-load

(b) on overload

(c) on leading power factor

(d) on zero power factor Ans: c

103. A transformer transforms

(a) voltage

(b) current

(c) current and voltage

(d) power

Ans: d

104. Which of the following is not the standard voltage for power supply in India ?

(a) llkV

(b) 33kV

(c) 66 kV

(d) 122 kV

Ans: d

105. Reduction in core losses and increase in permeability are obtained with transformer employing

(a) core built-up of laminations of cold rolled grain oriented steel

(b) core built-up of laminations of hot rolled sheet

(c) either of the above

(d) none of the above

Ans: a

106. In a power or distribution transformer about 10 per cent end turns are heavily insulated

(a) to withstand the high voltage drop due to line surge produced by the shunting capacitance of the end turns

(b) to absorb the line surge voltage and save the winding of transformer from damage

(c) to reflect the line surge and save the winding of a transformer from damage

(d) none of the above

Ans: a

107. For given applied voltage, with the increase in frequency of the applied voltage

(a) eddy current loss will decrease

(b) eddy current loss will increase

(c) eddy current loss will remain unchanged

(d) none of the above

Ans: c

108. Losses which occur in rotating electric machines and do not occur in trans formers are

(a) friction and windage losses

(b) magnetic losses

(c) hysteresis and eddy current losses

(d) copper losses

Ans: a

109. In a given transformer for a given applied voltage, losses which remain constant irrespective of load changes are (a) hysteresis and eddy current losses

(b) friction and windage losses

(c) copper losses

(d) none of the above

Ans: a

110. Which of the following statements regarding an idel single-phase transformer having a turn ratio of 1 : 2 and drawing a current of 10 A from 200 V A.C. supply is incorrect ?

(a) Its secondary current is 5 A

(b) Its secondary voltage is 400 V

(c) Its rating is 2 kVA

(d) Its secondary current is 20 A

(e) It is a step-up transformer

Ans: d

111 The secondary of a current transformer is always short-circuited under operating conditions because it

(a) avoids core saturation and high voltage induction

(b) is safe to human beings

(c) protects the primary circuit

(d) none of the above

Ans: a

112. In a transformer the resistance between its primary and secondary should be (a) zero

(b) 10 Q

(c) 1000 Q

(d) infinity

Ans: d

113. A good voltage regulation of a transformer means

(a) output voltage fluctuation from no load to full load is least

(b) output voltage fluctuation with power factor is least

(c) difference between primary and secondary voltage is least

(d) difference between primary and secondary voltage is maximum Ans: a

114. For a transformer, operating at constant load current, maximum efficiency will occur at

(a) 0.8 leading power factor

(b) 0.8 lagging power factor

(c) zero power factor

(d) unity power factor

Ans: d

115. Which of the following protection is normally not provided on small distribution transformers ?

(a) Overfluxing protection

(b) Buchholz relay

(c) Overcurrent protection

(d) All of the above

Ans: b

116. Which of the following acts as a protection against high voltage surges due to lightning and switching ?

(a) Horn gaps

(b) Thermal overload relays

(c) Breather

(d) Conservator

Ans: a

117. The efficiency of two identical transformers under load conditions can be determined by (a) short-circuit test

(b) back-to-back test

(c) open circuit test

(d) any of the above

Ans: b

118. Which of the following insulating materials can withstand the highest temperature safely ? (a) Cellulose (b) Asbestos

(c) Mica

(d) Glass fibreAns: c

119. Which of the following parts of a transformer is visible from outside ?



(a) Bushings

(b) Core

(c) Primary winding

(d) Secondary winding

Ans: a

120. The noise produced by a transformer is termed as

(a) zoom

(b) hum

(c) ringing

(d) buzzAns: b

121. Which of the following loss in a transformer is zero even at full load ? (a) Core loss

(b) Friction loss

(c) Eddy current loss

(d) Hysteresis lossAns: b

122. Which of the following is the most likely source of harmonics in a transformer ? (a) poor insulation

(b) Overload

(c) loose connections

(d) Core saturation

Ans: d

123. If a transformer is continuously operated the maximum temperature rise will occur in (a) core

(b) windings

(c) tank

(d) any of the above

Ans: b

124. The hum in a transformer is mainly attributed to

(a) load changes

oil in the transformer

(c) magnetostriction

(d) mechanical vibrations

Ans: c

125. The maximum load that a power transformer can carry is limited by its

(a) temperature rise

(b) dielectric strength of oil

(c) voltage ratio

(d) copper loss

Ans: c

126. The efficiency of a transformer, under heavy loads, is comparatively low because

(a) copper loss becomes high in proportion to the output

(b) iron loss is increased considerably

(c) voltage drop both in primary and secondary becomes large

(d) secondary output is much less as compared to primary input Ans: a

127. An open-circuit test on a transformer is conducted primarily to measure

(a) insulation resistance

(b) copper loss

(c) core loss (d) total loss

(e) efficiency

(f) none of the above

Ans: c

128. A no-load test is performed on a transformer to determine

(a) core loss

(b) copper loss

(c) efficiency

(d) magnetising current

(e) magnetising current and loss

Ans: e

129. The voltage transformation ratio of a transformer is equal to the ratio of

(a) primary turns to secondary turns secondary current to primary current

(c) secondary induced e.m.f. to primary induced e.m.f.

(d) secondary terminal voltage to primary applied voltage Ans: c

130. Part of the transformer which is most subject to damage from overheating is

(a) iron core

(b) copper winding

(c) winding insulation

(d) frame or case

(e) transformer tank

Ans: c

131. If a transformer is switched on to a voltage more than the rated voltage

(a) its power factor will deteriorate

(b) its power factor will increase

(c) its power factor will remain unaffected

(d) its power factor will be zero Ans: a

132. Auto-transformer makes effective saving on copper and copper losses, when its transformation ratio is

(a) approximately equal to one

(b) less than one

(c) great than one

(d) none of the above

Ans: a

133. Minimum voltage regulation occurs when the power factor of the load is (a) unity

(b) lagging

(c) leading

(d) zeroAns: c

134. In a step-down transformer, there is a change of 15 A in the load current. This results in change of supply current of

(a) less than 15 A more than 15 A


(c) 15 A

(d) none of the above

Ans: a

135. The efficiencies of transformers compared with that of electric motors of the same power are (a) about the same

(6) much smaller

(c) much higher

(d) somewhat smaller

(e) none of the above Ans: c